OrthoGain

Evidence & safety

Scientific evidence

OrthoGain evidence: exosome NTA, growth factor ELISA and safety

At OrthoGain, scientific transparency is an important part of product communication. We focus on measurable analytical characterisation of the final preparation.

01 · Nanoparticle Tracking Analysis

Particle concentration & size

NTA is an analytical technique used to evaluate nanoparticles through their Brownian motion and light-scattering behaviour. It provides information about particle concentration, particle size distribution and the distribution profile of detected particles.

NTA results: particle concentration by size, and intensity by size scatter plot
2.05×1013particles/ml

Particle concentration

Reported nanoparticle concentration in the final preparation.

85.7%

Size distribution

Of detected particles between 30–150 nm.

5growth factors

Quantified by ELISA

PDGF, VEGF, TGF-β, EGF and bFGF, alongside the particle data.

Note: NTA provides information about the nanoparticle population. It does not independently establish exosome identity or purity. The full NTA report is available to healthcare professionals on request.

02 · Enzyme-Linked Immunosorbent Assay

Growth factor concentration

ELISA quantifies selected proteins and growth factors in a biological sample. OrthoGain’s assessment covers PDGF, VEGF, TGF-β, EGF and bFGF — information about their concentration in the final preparation.

PDGF · axis 0–100,000 pg/ml

PDGF 99,443.75
025,00050,00075,000100,000

VEGF, bFGF, TGF-β, EGF · axis 0–4,000 pg/ml

VEGF 3,899
bFGF 2,793
TGF-β 1,732.50
EGF 550
01,0002,0003,0004,000
Source: Sandwich ELISA (enzyme-linked immunosorbent assay), iCrest Biotechnologies Ltd, Bengaluru; final report dated 7 November 2025 (sample collected 29 October 2025). Values are from a single plasma sample of the OrthoGain preparation (n = 1), not a mean across donors. The full assay report is available to clinicians on request.
View the data as a table
Growth factorConcentrationUnitAssociated role
PDGF99,443.75pg/mlFibroblast recruitment, connective tissue repair
VEGF3,899pg/mlAngiogenesis, tissue vascularisation
bFGF2,793pg/mlCell proliferation and migration
TGF-β1,732.50pg/mlExtracellular matrix, collagen synthesis
EGF550pg/mlCellular proliferation, epithelial repair

03 · Scientific transparency

Verifiable analytical documentation

Analytical characterisation

We believe scientific information should be supported by verifiable analytical documentation. Available for professional evaluation:

NTA analytical reportELISA analytical reportProduct technical dossierManufacturing and regulatory documentation
Request documentation

Clinical evidence

Analytical characterisation and clinical efficacy are separate areas of evidence. Clinical benefits for individual orthopaedic indications should be established through appropriately designed clinical studies.

Our commitment: transparent scientific communication, responsible clinical positioning and continued evaluation of regenerative technologies.

Safety

Patient-specific. Autologous. Professionally prepared.

OrthoGain is designed as an autologous preparation system using blood-derived material from the individual patient.

Autologous source

The preparation uses the patient’s own blood-derived components, avoiding the use of donor-derived biological material.

Single-patient use

The kit is intended for individual patient preparation. Disposable components must not be reused or shared between patients.

Controlled preparation

The preparation process follows a defined sequence of collection, separation, processing and filtration.

Professional administration

To be handled and administered by qualified healthcare professionals following aseptic technique.

Patient assessment

Appropriate patient selection, medical history assessment and clinical evaluation are essential before any procedure.

Precautions & adverse events

As with blood collection and injection procedures, local pain, tenderness, bruising, swelling or other reactions may occur.

Our safety commitment: patient safety, professional training, proper handling and transparent documentation remain central to the OrthoGain approach. For healthcare professionals: request the technical documentation before clinical use. Report any suspected adverse event to [email protected].

For orthopaedic surgeons, sports medicine specialists, hospitals & healthcare professionals

Innovation that supports regeneration.

Advancing biological science. Exploring new possibilities. Supporting better healthcare.